18 - 150
18EtherCAT COMMUNICATION
(6) Parameter error list (2A45h)
Index
Sub
Name
Data Type
Access
PDO Mapping
2A45h
0
Parameter error list
UNSIGNED8
ro
Impossible
1
No. 1
UNSIGNED16
16
No. 16
Index
Sub
Default
Range
Units
EEP-ROM
Parameter
2A45h
0
10h to 10h (16)
Impossible
1
0000h to FFFFh
16
A list of parameter No. in which [AL. 37 Parameter error] has occurred is returned. The description of
2A45h: 1 to 2A45h: 16 is as follows. If [Pr. PC01] is an error factor, "0201h" is returned. If more than 17
parameter errors have occurred, the 17th and later parameter errors are returned after the parameters
are corrected and the power is cycled.
Bit
Description
0 to 7
Parameter number
8 to 15
Parameter group number
00: [Pr. PA _ _ ]
01: [Pr. PB _ _ ]
02: [Pr. PC _ _ ]
03: [Pr. PD _ _ ]
04: [Pr. PE _ _ ]
05: [Pr. PF _ _ ]
06: Parameter for manufacturer setting
07: Parameter for manufacturer setting
08: Parameter for manufacturer setting
09: Parameter for manufacturer setting
0A: Parameter for manufacturer setting
0B: [Pr. PL _ _ ]
0C: [Pr. PT _ _ ]
0E: [Pr. PN _ _ ]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals