19EtherNet/IP COMMUNICATION
(4) Current alarm (2A41h)
Ins ID
Attr ID
Access
Name
Data Type
2A41h
0
Get
Current alarm
UDINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2A41h
0
00000000h to FFFFFFFFh
Impossible
The number of the current alarm is returned. When no alarm has occurred, "00000000h" is returned. The
description of the values is as follows. If [AL. 16.3] occurs, "00160003h" is returned.
Bit
Description
0 to 15
Alarm detail No.
16 to 31
Alarm No.