19 - 131
19EtherNet/IP COMMUNICATION
(6) Parameter error list (2A45h)
Ins ID
Attr ID
Access
Name
Data Type
2A45h
0
Get
Parameter error list
USINT
1
No. 1
UINT
16
No. 16
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2A45h
0
10h to 10h (16)
Impossible
1
0000h to FFFFh
16
When [AL. 37 Parameter error] has occurred, the number of the parameter which causes the error is
returned. The descriptions of 2A45h: 1 to 2A45h: 16 are as follows. If [Pr. PC01] is an error factor, 0201h
is returned. If more than 17 parameter errors have occurred, the 17th and later parameter errors are
returned after the parameters are corrected and the power is cycled.
Bit
Description
0 to 7
Parameter number
8 to 15
Parameter group number
00: [Pr. PA _ _ ]
01: [Pr. PB _ _ ]
02: [Pr. PC _ _ ]
03: [Pr. PD _ _ ]
04: [Pr. PE _ _ ]
05: [Pr. PF _ _ ]
06: Parameter for manufacturer setting
07: Parameter for manufacturer setting
08: Parameter for manufacturer setting
09: Parameter for manufacturer setting
0A: Parameter for manufacturer setting
0B: [Pr. PL _ _ ]
0C: [Pr. PT _ _ ]
0E: [Pr. PN _ _ ]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals