EasyManuals Logo

SMC Networks LECSN-T Series User Manual

SMC Networks LECSN-T Series
1046 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #806 background imageLoading...
Page #806 background image
19 - 148
19EtherNet/IP COMMUNICATION
(16) Control DI 7 (2D07h)
Ins ID
Attr ID
Access
Name
Data Type
2D07h
0
Get/Set
Control DI 7
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2D07h
0
0
Refer to the text.
Impossible
Set control commands to control the driver. Refer to section 5.2.2 (4) for details.
(17) Control DI 10 (2D0Ah)
Ins ID
Attr ID
Access
Name
Data Type
2D0Ah
0
Get/Set
Control DI 10
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2D0Ah
0
0
Refer to the text.
Impossible
Set control commands to control the driver. Refer to section 5.2.2 (5) for details.
(18) Status DO 1 (2D11h)
Ins ID
Attr ID
Access
Name
Data Type
2D11h
0
Get
Status DO 1
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2D11h
0
Refer to the text.
Impossible
The servo status is returned. Refer to section 5.3.2 (1) for details.
(19) Status DO 2 (2D12h)
Ins ID
Attr ID
Access
Name
Data Type
2D12h
0
Get
Status DO 2
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2D12h
0
Refer to the text.
Impossible
The servo status is returned. Refer to section 5.3.2 (2) for details.
(20) Status DO 3 (2D13h)
Ins ID
Attr ID
Access
Name
Data Type
2D13h
0
Get
Status DO 3
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2D13h
0
Refer to the text.
Impossible
The servo status is returned. Refer to section 5.3.2 (3) for details.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals