20.PROFINET COMMUNICATION
(42) Alarm Monitor 12 Within one-revolution position (P11148)
The position within one-revolution at alarm occurrence is returned.
Alarm Monitor 12 Within
one-revolution position
Position within one-revolution at alarm
occurrence
(43) Alarm Monitor 13 ABS counter (P11149)
The ABS counter at alarm occurrence is returned.
Alarm Monitor 13 ABS
counter
ABS counter at alarm occurrence
(44) Alarm Monitor 14 Load to motor inertia ratio (P11150)
The load to motor inertia ratio at alarm occurrence is returned.
Alarm Monitor 14 Load
to motor inertia ratio
Load to motor inertia ratio at alarm
occurrence
(45) Alarm Monitor 15 Bus voltage (P11151)
The bus voltage at alarm occurrence is returned.
Alarm Monitor 15 Bus
voltage
Bus voltage at alarm occurrence
(46) Alarm Monitor 16 Load-side cumulative feedback pulses (P11152)
The load-side cumulative feedback pulses at alarm occurrence are returned.
Alarm Monitor 16
Load-side cumulative
feedback pulses
Load-side cumulative feedback pulses at