20.PROFINET COMMUNICATION
(10) Vibration level during motor operating (P11304)
Vibration level during operation can be obtained. Refer to section 8.9 for details.
Vibration level during
motor operating
Vibration level during motor operating
(11) Control DI 1 (P11521)
Set control commands to control the driver. For details, refer to section 5.3.1 (2).
(12) Control DI 2 (P11522)
Set control commands to control the driver. For details, refer to section 5.3.1 (3).
(13) Control DI 3 (P11523)
Set control commands to control the driver. For details, refer to section 5.3.1 (4).
(14) Status DO 1 (P11537)
The servo status is returned. Refer to section 5.3.2 (3) for details.
(15) Status DO 2 (P11538)
The servo status is returned. Refer to section 5.3.2 (4) for details.