20 - 150
20PROFINET COMMUNICATION
(29) One-touch tuning Stop (P11602)
One-touch tuning stop command is issued. Writing "1EA5h" stops one-touch tuning.
PNU
Sub
Access
Name
Data Type
Description
Default
11602
0
W
One-touch tuning Stop
Unsigned16
Stop of one-touch tuning
PNU
Sub
Range
Units
EEP-ROM
Parameter
11602
0
0000h, 1EA5h
Impossible
(30) One-touch tuning Clear (P11603)
The parameter changed in one-touch tuning is returned to the value before the change.
PNU
Sub
Access
Name
Data Type
Description
Default
11603
0
W
One-touch tuning Clear
Unsigned16
The parameter changed in one-touch
tuning is returned to the value before the
change.
PNU
Sub
Range
Units
EEP-ROM
Parameter
11603
0
0000h to 0001h
Impossible
The following settings are available.
Setting
value
Description
0000
Restores the initial value.
0001
Restores the value before one-touch tuning.
(31) One-touch tuning Error Code (P11604)
An error code of the one-touch tuning is returned.
PNU
Sub
Access
Name
Data Type
Description
Default
11604
0
R
One-touch tuning Error
Code
Unsigned16
One-touch tuning error code
PNU
Sub
Range
Units
EEP-ROM
Parameter
11604
0
0000h to C00Fh
Impossible
The following error codes are available.
Value
Description
0000
Finished normally
C000
Tuning canceled
C001
Overshoot exceeded
C002
Servo-off during tuning
C003
Control mode error
C004
Time-out
C005
Inertia estimation failed
C00F
One-touch tuning disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals