Frequency setpoint selection
via analog input 1
(standard setpoint source)
Automatic setpoint selection active [107]
Rotational direction reversed [69]
Manual setpoint selection active [106]
Running [50]
Stop active [53]
Digital input 1 [11] Run
Constant TRUE [1]
Digital input 3 [13]
Digital input 2 [12]
Manual
frequency setpoint selection
via keypad
Enable inverter
Output signals
Status signals
Output frequency
Activate keypad setpoint
Invert rotation
Input signals
FunctionTrigger
The status signals can be assigned to digital outputs. 4Congure digital outputs^ 263
Change-over from analog input 1 (standard setpoint source) to keypad setpoint.
Change-over from keypad setpoint back to analog input 1 (standard setpoint source).
Conguring the frequency control
Changing the setpoint source during operaon
Example: Change-over from AI1 setpoint to keypad setpoint