17.4.2 Network diagnoscs
The following parameters show some general informaon with regard to the network opon
available and the network.
Parameter
Address Name / seng range / [default seng] Info
0x282B:005
(P125.05)
Inverter diagnoscs: Most recently used control regis-
ter
(Inverter diag.: Netw. contr.reg.)
•
Read only
Display of the network register for the control that was accessed last
(e. g. 0x6040 or 0x400B:1).
•
Format: 0xiiiiss00 (iiii = hexadecimal index, ss = hexadecimal subindex)
•
The lowest byte is always 0x00.
0x282B:006
(P125.06)
Inverter diagnoscs: Most recently used setpoint reg-
ister
(Inverter diag.: Netw. setp.reg.)
•
Read only
Display of the network register for setpoint selecon that was accessed
last (e. g. 0x6042 or 0x400B:3).
•
Format: 0xiiiiss00 (iiii = hexadecimal index, ss = hexadecimal subindex)
•
The lowest byte is always 0x00.
0x231F:001
(P500.01)
Module ID: Acve module ID
(Module ID: Acve module ID)
•
Read only
Display of the network opons currently congured in the inverter.
•
With the help of this module ID, the keypad only shows the communi-
caon parameters relevant to the respecve network.
Note!
When switched on, the inverter checks whether the parameter sengs
saved in the memory module match the inverter hardware and rm-
ware. In case of an incompability, a corresponding error message is
output. For details see chapter "Behaviour of the inverter in case of
incompable data in the memory module" (secon "Hardware and rm-
ware updates/downgrades"). ^ 516
48 No network
67 CANopen
71 EtherNet/IP (from version 02.00)
72 BACnet
78 POWERLINK (from version 05.00)
80 PROFIBUS
82 PROFINET (from version 02.00)
84 EtherCAT (from version 02.00)
86 Modbus TCP/IP
87 Modbus
0x231F:002
(P500.02)
Module ID: Module ID connected
(Module ID: Module ID conn.)
•
Read only
Display of the network opon currently available in the inverter.
Note!
When switched on, the inverter checks whether the parameter sengs
saved in the memory module match the inverter hardware and rm-
ware. In case of an incompability, a corresponding error message is
output. For details see chapter "Behaviour of the inverter in case of
incompable data in the memory module" (secon "Hardware and rm-
ware updates/downgrades"). ^ 516
48 No network Display of the network opons currently congured in the inverter.
•
With the help of this module ID, the keypad only shows the communi-
caon parameters relevant to the respecve network.
Note!
When switched on, the inverter checks whether the parameter sengs
saved in the memory module match the inverter hardware and rm-
ware. In case of an incompability, a corresponding error message is
output. For details see chapter "Behaviour of the inverter in case of
incompable data in the memory module" (secon "Hardware and rm-
ware updates/downgrades"). ^ 516
67 CANopen
71 EtherNet/IP (from version 02.00)
72 BACnet
78 POWERLINK (from version 05.00)
80 PROFIBUS
82 PROFINET (from version 02.00)
84 EtherCAT (from version 02.00)
86 Modbus TCP/IP
87 Modbus
Related topics
4Conguring the network ^ 280
Diagnoscs and fault eliminaon
Diagnosc parameters
Network diagnoscs