10.4.10 Addive voltage impression
This funcon serves to boost (or lower) the motor voltage from the process via an addive
voltage setpoint in order to realise a load adjustment (for instance in case of winder applica-
ons).
NOTICE
A too high boost of the motor voltage may cause the motor to heat up strongly due to the
resulng current.
▶
Avoid a too high boost of the motor voltage!
The funcon is equally suitable for the closed loop V/f characterisc control.
Details
At a constant eld frequency, the output voltage of the inverter can be changed within a wide
range.
Example: Adaptaon of the voltage characterisc in case of V/f characterisc control as a
funcon of the load:
•
Clockwise rotaon (CW) is operaon in motor mode: Boost voltage.
•
Counter-clockwise rotaon (CCW) is operaon in generator mode: Lower voltage.
f
V
out
V/f characteristic
Operation in
generator mode
Operation in
motor mode
①
Selecng an addive voltage setpoint
Parameter
Address Name / seng range / [default seng] Info
0x2B13:001 Addive voltage impression: Enable Funcon
•
From version 02.00
1 = enable funcon.
0 Disable
1 Enable
0x2B13:002 Addive voltage impression: Setpoint source
•
From version 02.00
Selecon of the source for specifying the addive voltage setpoint.
•
100 % ≡ Rated voltage 0x2C01:007 (P320.07)
1 Analog input 1
2 Analog input 2
3 Network The addive voltage setpoint is dened via the mappable NetWordIN5
0x4008:005 (P590.05)data word.
201 Internal value (from version 05.03) Internal values of the manufacturer.
202 Internal value (from version 05.03)
203 Internal value (from version 05.03)
204 Internal value (from version 05.03)
205 Internal value (from version 05.03)
206 Internal value (from version 05.03)
0x2B13:003 Addive voltage impression: Actual voltage
•
Read only: x V
•
From version 02.00
Display of the current (boosted or lowered) voltage.
Conguring the motor control
V/f characterisc control for asynchronous motor (VFC open loop)
Addive voltage impression
190