12.6.6.4 Switched on
This is the device state of the inverter aer the "Switch on" command has been triggered in
the "Ready to switch on" device state.
•
Process data monitoring is acve.
•
Communicaon is possible.
•
The DC-bus voltage is available.
•
The inverter can be parameterised.
•
If the internal holding brake control (0x2820:001 (P712.01)) is acve in the inverter, the
motor brake is closed.
•
Operaon is inhibited.
1 From all states
2 Power secon inhibited (pulse inhibit)
3 Power secon enabled
Bit paern in the CiA 402 status word (0x6041 (P780.00))
Bit 15 ... 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
(specic)
Warning
acve
Operaon
inhibited
Quick stop
acve
DC bus ready
for operaon
Fault acve Operaon
enabled
Switched on Ready to
switch on
X X 1 1 X 0 0 1 1
X = state is not relevant
Conguring the network
Device prole CiA 402
Device states
322