14.2 Parameter change-over
For up to 32 freely selectable parameters, this funcon provides a change-over between four
sets with dierent parameter values.
DANGER!
Changed parameter sengs can become eecve immediately depending on the acvang
method set in 0x4046 (P755.00).
The possible consequence is an unexpected response of the motor sha while the inverter is
enabled.
If possible, only carry out parameter changes while the inverter is disabled.
Certain device commands or sengs which might cause a crical state of the drive behav-
iour can generally only be carried our when the inverter is inhibited.
Details
The parameter list is compiled in the same way as that of the "Favorites" via congura-
on. »EASY Starter« provides a user-friendly parameterisaon dialog for this purpose.
Change-over to another value set can oponally be eected via corresponding device com-
mands and/or special funcons/triggers:
4Device commands for parameter change-over^ 528
4Funcons for parameter change-over^ 530
Addional funcons
Parameter change-over
525