12.15.6 Diagnoscs
12.15.6.1 LED status display
Informaon about the PROFIBUS status can be obtained quickly via the "NS" and "NE" LED
displays on the front of the inverter.
The meaning can be seen from the table below.
LED "NS" (green) LED "NE" (red) Status/meaning
o o No supply voltage available, network deacvated, not inialised, or rmware download acve.
on
Connected with master, control running, "Data Exchange" state acve.
blinking
Not connected, control stopped, or no data exchange.
blinking blinking
Watchdog monitoring me elapsed.
Any
Flashing
PROFIBUS parameterisaon error.
Flashing 2 x
PROFIBUS conguraon error.
o on
Invalid staon address set or non-correctable error.
12.15.6.2 Informaon on the network
The following parameters show informaon on the network.
Parameter
Address Name / seng range / [default seng] Info
0x2342:001
(P511.01)
Acve PROFIBUS sengs: Acve staon address
(PROFIBUS diag.: Act.staon addr)
•
Read only
Display of the acve staon address.
0x2342:002
(P511.02)
Acve PROFIBUS sengs: Acve baud rate
(PROFIBUS diag.: Acve baud rate)
•
Read only
Display of the acve baud rate.
0 12 Mbps
1 6 Mbps
2 3 Mbps
3 1.5 Mbps
4 500 kbps
5 187.5 kbps
6 93.75 kbps
7 45.45 kbps
8 19.2 kbps
9 9.6 kbps
15 Search Automac baud rate detecon acve.
0x2342:003
(P511.03)
Acve PROFIBUS sengs: Watchdog me
(PROFIBUS diag.: Watchdog me)
•
Read only
Display of the watchdog monitoring me specied by the master.
•
Monitoring starts with the arrival of the rst telegram.
•
When a value of "0" is displayed, the monitoring funcon is deacva-
ted.
•
A change in the watchdog monitoring me in the master is eecve
immediately.
0x2343
(P509.00)
PROFIBUS switch posion
(PROFIBUS switch)
•
Read only
Display of the DIP switch seng at the last mains power-on.
•
The displayed value corresponds to the sum of the individual DIP
switch values 1 ... 64.
0x2344:001
(P512.01)
PROFIBUS Conguraon: Extended diagnosc bit
(PROFIBUS Cong.: Ext. diag. bit)
1 = set external diagnosc bit ("Diag Bit").
•
The diagnosc bit is sent to the master where it is evaluated sepa-
rately.
0 Delete
1 Set
Conguring the network
PROFIBUS
Diagnoscs