12.14.6 Diagnoscs
Errors and warnings of the inverter and the network opon are sent as extended diagnosc
messages to the managing node:
Bytes Meaning Value [hex]
1 ... 6 Diagnosc block header 0x0010 001C 0100
7 ... 8 Alarm type 0x0001 (diagnoscs)
9 ... 12 API (Applicaon Programming Interface) 0x0000 0000
13, 14 Slot number 0x0001 / 0x0002
15, 16 Subslot number 0x0001
17 ... 20 Module ID ID according to module
21 ... 24 Submodule number ID according to module
25, 26 Alarm specicaon 0xB000
27, 28 User structure ID 0x0001
29 ... 32 Error code
4Error codes, causes and remedies^ 616
12.14.6.1 LED status display
Informaon on the network status can be obtained quickly via the "Status" and "Error" LED
displays on the front of the inverter. In addion, the LEDs at the RJ45 sockets indicate the
POWERLINK connecon status .
The meaning can be seen from the table below.
LED "Status" (green) NMT communicaon status Meaning
o - The network opon is not supplied with voltage, is not acve at the net-
work or is in the INIT state.
Flashing
NMT_CS_PREOPERATIONAL_1 The POWERLINK network is in the inialisaon phase.
Flashing 2 x
NMT_CS_PREOPERATIONAL_2 The POWERLINK network is in the inialisaon phase with cyclic trac.
Flashing 3 x
NMT_CS_READY_TO_OPERATE The network opon waits for the start signal.
ickers
NMT_CS_BASIC_ETHERNET The network opon has not found a managing node and is in the "Basic
Ethernet Mode” mode.
blinking
NMT_CS_STOPPED The network opon is in the "Stopped" state (waing for switch-o).
on
NMT_CS_OPERATIONAL The network opon is in the operang phase.
LED "Error" (red) Status/meaning
on
POWERLINK network error
Status displays at the RJ45 sockets
The LEDs at the RJ45 sockets indicate the connecon status to the network:
LED (green) Status/meaning
o No connecon to the network.
on
A physical connecon to the network is available.
ickers
Data is exchanged via the network.
LED (red) Status/meaning
on
POWERLINK collision