4.4.4.2 Favourites parameter list (default seng)
In the default seng, parameters for resolving typical applicaons are dened as "Favorites”.
No. Display code Designaon Default seng Seng range Info
1 P100.00 Output frequency x.x Hz - (Read only) 0x2DDD
2 P103.00 Current actual x.x % - (Read only) 0x6078
3 P106.00 Motor voltage x VAC - (Read only) 0x2D89
4 P150.00 Error code - - (Read only) 0x603F
5 P200.00 Control select. Flexible I/O [0] Selecon list 0x2824
6 P201.01 Freq. setp. src. Analog input 1 [2] Selecon list 0x2860:001
7 P203.01 Start method Normal [0] Selecon list 0x2838:001
8 P203.03 Stop method Standard ramp [1] Selecon list 0x2838:003
9 P208.01 Mains voltage 230 Ve [0] Selecon list 0x2540:001
10 P210.00 Min. frequency 0.0 Hz 0.0 ... 599.0 Hz 0x2915
11 P211.00 Max. frequency 50.0 Hz* | 60.0 Hz** 0.0 ... 599.0 Hz 0x2916
12 P220.00 Accelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2917
13 P221.00 Decelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2918
14 P300.00 Motor ctrl mode VFC open loop [6] Selecon list 0x2C00
15 P302.00 V/f charac.shape Linear [0] Selecon list 0x2B00
16 P303.01 Base voltage 230 V 0 ... 5000 V 0x2B01:001
17 P303.02 Base frequency 50 Hz* | 60 Hz** 0 ... 1500 Hz 0x2B01:002
18 P304.00 Limit. rotaon Both rot. direct [1] Selecon list 0x283A
19 P305.00 Switching freq. 0 1 ... 33 0x2939
20 P306.01 Duty selecon Heavy Duty [0] Selecon list 0x2D43:001
21 P308.01 Max.load.for 60s 150 % 30 ... 200 % 0x2D4B:001
22 P316.01 Fixed V/f boost 2.5 % 0.0 ... 20.0 % 0x2B12:001
23 P323.00 Motor current 1.700 A 0.001 ... 500.000 A 0x6075
24 P324.00 Max current 200.0 % 0.0 ... 3000.0 % 0x6073
25 P400.01 Enable inverter TRUE [1] Trigger list ^ 64 0x2631:001
26 P400.02 Run Digital input 1 [11] Trigger list ^ 64 0x2631:002
27 P400.03 Quick stop Not connected [0] Trigger list ^ 64 0x2631:003
28 P400.04 Reset fault Digital input 2 [12] Trigger list ^ 64 0x2631:004
29 P400.05 DC braking Not connected [0] Trigger list ^ 64 0x2631:005
30 P400.06 Start forward Not connected [0] Trigger list ^ 64 0x2631:006
31 P400.07 Start reverse Not connected [0] Trigger list ^ 64 0x2631:007
32 P400.08 Run forward Not connected [0] Trigger list ^ 64 0x2631:008
33 P400.09 Run reverse Not connected [0] Trigger list ^ 64 0x2631:009
34 P400.13 Reverse rot.dir. Digital input 3 [13] Trigger list ^ 64 0x2631:013
35 P400.18 Setp: Preset b0 Digital input 4 [14] Trigger list ^ 64 0x2631:018
36 P400.19 Setp: Preset b1 Digital input 5 [15] Trigger list ^ 64 0x2631:019
37 P400.20 Setp: Preset b2 Not connected [0] Trigger list ^ 64 0x2631:020
38 P420.01 Relay funcon Rdy for operat. [51] Selecon list 0x2634:001
39 P420.02 DO1 funcon Release brake [115] Selecon list 0x2634:002
40 P430.01 AI1 input range 0 ... 10 VDC [0] Selecon list 0x2636:001
41 P430.02 AI1 freq @ min 0.0 Hz -1000.0 ... 1000.0 Hz 0x2636:002
42 P430.03 AI1 freq @ max 50.0 Hz* | 60.0 Hz** -1000.0 ... 1000.0 Hz 0x2636:003
43 P440.01 AO1 outp. range 0 ... 10 VDC [1] Selecon list 0x2639:001
44 P440.02 AO1 funcon Outp. frequency [1] Selecon list 0x2639:002
45 P440.03 AO1 min. signal 0 -2147483648 ... 2147483647 0x2639:003
46 P440.04 AO1 max. signal 1000 -2147483648 ... 2147483647 0x2639:004
47 P450.01 Freq. preset 1 20.0 Hz 0.0 ... 599.0 Hz 0x2911:001
48 P450.02 Freq. preset 2 40.0 Hz 0.0 ... 599.0 Hz 0x2911:002
49 P450.03 Freq. preset 3 50.0 Hz* | 60.0 Hz** 0.0 ... 599.0 Hz 0x2911:003
50 P450.04 Freq. preset 4 0.0 Hz 0.0 ... 599.0 Hz 0x2911:004
* Device for 50-Hz mains ** Device for 60-Hz mains
Commissioning
General informaon on parameter seng
Favourites
33