17 Diagnoscs and fault eliminaon
This secon contains informaon on error handling, drive diagnoscs and fault analysis.
17.1 LED status display
The "RDY" and "ERR" LED status displays on the front of the inverter provide some quick infor-
maon about certain operang states.
"RDY" LED (blue) "ERR" LED (red) Status/meaning
o o No supply voltage.
on on
Inialisaon (inverter is started.)
blinking (1 Hz)
o
Safe torque o (STO) acve. The inverter has been disabled by the integrated safety system.
4Safe Torque O (STO) ^ 548
blinking fast (4 Hz)
Safe torque o (STO) acve, warning present. The inverter has been disabled by the integrated
safety system.
blinking (2 Hz)
o Inverter inhibited.
blinking fast (4 Hz)
Inverter disabled, warning acve.
4Error handling ^ 610
on
Inverter disabled, error acve.
4Error handling ^ 610
lit every 1.5 s for a
short me
Inverter inhibited, no DC-bus voltage.
on for a short me
every 1 s
USB module is connected, 5-V supply voltage for the USB module is available.
on
o
Inverter enabled.
The motor rotates according to the specied setpoint or quick stop acve.
blinking fast (4 Hz)
Inverter enabled, warning acve.
The motor rotates according to the specied setpoint or quick stop acve.
blinking (1 Hz)
Inverter enabled, quick stop as response to fault acve.
4Error handling ^ 610
Both LEDs are blinking in a rapidly alternang
mode
Firmware update acve.
4Update device rmware ^ 514
Both LEDs are blinking in a very rapidly synchro-
nous mode
"Visual tracking" funcon is acve.
4Opcal device idencaon ^ 495
Diagnoscs and fault eliminaon
LED status display
593