EasyManua.ls Logo

Lenze i550

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Name / seng range / [default seng] Info
0x4042:001 ...
0x4042:032
(P751.01 ... 32)
Parameter value set 1: Value of parameter 1 ... Value
of parameter 32
(Par. value set 1: Set 1 - Value 1 ... Set 1 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 1 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4043:001 ...
0x4043:032
(P752.01 ... 32)
Parameter value set 2: Value of parameter 1 ... Value
of parameter 32
(Par. value set 2: Set 2 - Value 1 ... Set 2 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 2 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4044:001 ...
0x4044:032
(P753.01 ... 32)
Parameter value set 3: Value of parameter 1 ... Value
of parameter 32
(Par. value set 3: Set 3 - Value 1 ... Set 3 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 3 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4045:001 ...
0x4045:032
(P754.01 ... 32)
Parameter value set 4: Value of parameter 1 ... Value
of parameter 32
(Par. value set 4: Set 4 - Value 1 ... Set 4 - Value 32)
-2147483648 ... [0] ... 2147483647
Value set 4 for the parameter list dened in 0x4041:001 ... 0x4041:032
(P750.01 ... 32).
0x4047:001
(P756.01)
Parameter change-over error message: Status
(PSet error msg.: Status)
Read only
Error message for the "parameter change-over" funcon.
In the event of an error, an error status is shown here, and in
0x4047:002 (P756.02) the number of the list entry in which the error
has occurred is displayed (in connecon with the value set selected).
If several errors occur at the same me, only the rst incorrect list
entry will be displayed. Hence, aer eliminaon of the displayed error
and repeated acvaon, more errors may be displayed.
The parameter list will always be processed from beginning to end,
even if errors occur in the meanme.
0 No fault
33803 Invalid data type
33804 Range violaon
33806 Invalid index
33813 No element selected
33815 Wring impermissible
33816 Device not inhibited
33829 Invalid subindex
33837 Access impermissible
33860 Parameter not mappable
33865 No subindexes
33876 Parameter not changeable
0x4047:002
(P756.02)
Parameter change-over error message: List entry
(PSet error msg.: List entry)
Read only
Error message for the "Parameter set changeover" funcon.
In the event of an error, the number of the list entry for which the
error displayed in 0x4047:001 (P756.01) has occurred is shown here.
14.2.3 Device commands for parameter change-over
The parameter set can be selected with the device commands "Load parameter set 1" ...
"Load parameter set 4".
Details
The change-over via the device commands depends on the acvaon method set in 0x4046
(P755.00):
Acvaon method = 1 or 3: Change-over takes place immediately.
Acvaon method = 0 or 2: The respecve device command is only executed if the inver-
ter is disabled.
Parameter
Address Name / seng range / [default seng] Info
0x2022:007
(P700.07)
Device commands: Load parameter set 1
(Device commands: Load par. set 1)
1 = load value set 1 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4042/1...32.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
Addional funcons
Parameter change-over
Parameter set conguraon
528

Table of Contents

Other manuals for Lenze i550

Related product manuals