Address Name / seng range / [default seng] Info
0x4018:004 Relay: Switch-on delay
0.000 ... [0.000] ... 65.535 s
Switch-on delay for the relay.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the decelera-
on me set in 0x2820:012 (P712.12)for closing the holding brake inu-
ences the me-dependent behaviour of the relay.
0x4018:005 Relay: Relay state
Read only
Display of the logic state of the relay.
0 FALSE
1 TRUE
0x4018:006 Relay: Trigger signal state
Read only
Display of the logic state of the trigger signal for the relay (without tak-
ing a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
0x4018:007 Relay: Switching cycles
Read only
Display of the previous relay switching cycles.
11.3.2 Digital output 1
Sengs for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in 0x2634:002 (P420.02).
The following sengs are possible for the digital output:
Inversion
Switch-on delay
Cutout delay
DO1
0x4016:0050x4016:006
1
0
1
0x2635 002: 0x4016 004: 0x4016:003
0x2634:002
X3
Trigger
Diagnosc parameters:
The logic status of the trigger signal is displayed in 0x4016:006.
The logic status of the digital output is displayed in 0x4016:005.
Parameter
Address Name / seng range / [default seng] Info
0x2634:002
(P420.02)
Digital outputs funcon: Digital output 1
(Dig.out.funcon: DO1 funcon)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to digital output 1.
Trigger = FALSE: X3/DO1 set to LOW level.
Trigger = TRUE: X3/DO1 set to HIGH level.
Notes:
An inversion set in 0x2635:002 (P421.02) is taken into consideraon
here.
115 Release holding brake Trigger signal for releasing the holding brake (TRUE = release holding
brake).
Note!
If this trigger is assigned to the relay or a digital output, the deceleraon
mes set for the respecve output are not eecve (are internally set to
"0"). Only the deceleraon me set in 0x2820:012 (P712.12) for closing
the holding brake inuences in this case the me-dependent behaviour
of the output.
4Holding brake control^ 203
100 Sequencer controlled (from version 03.00) The control is executed via the sequencer (according to the congura-
on of the digital outputs for the current segment).
4Segment conguraon ^ 93
0x2635:002
(P421.02)
Inversion of digital outputs: Digital output 1
(DO inversion: DO1 inversion)
Inversion of digital output 1
0 Not inverted
1 Inverted
I/O extensions and control connecons
Congure digital outputs
Relay output
267