12.10.7.2 Informaon on the network
The following parameters show informaon on the network.
Parameter
Address Name / seng range / [default seng] Info
0x2362:001
(P511.01)
Acve EtherCAT sengs: EoE IP address
(EtherCAT diag.: EoE IP address)
Read only
0x2362:002
(P511.02)
Acve EtherCAT sengs: EoE subnet mask
(EtherCAT diag.: EoE subnet mask)
Read only
From version 05.01
0x2362:003
(P511.03)
Acve EtherCAT sengs: EoE gateway
(EtherCAT diag.: EoE gateway)
Read only
0x2362:004
(P511.04)
Acve EtherCAT sengs: Device idener
(EtherCAT diag.: Device ident.)
Read only
From version 02.00
Display of the clear device address in the network which is dened via
rotary encoder switch or object 0x2361:004 (P510.04).
0x2362:005
(P511.05)
Acve EtherCAT sengs: EoE virtual MAC address
(EtherCAT diag.: EoE virt MAC add)
Read only
From version 02.00
0x2362:006
(P511.06)
Acve EtherCAT sengs: Staon address
(EtherCAT diag.: Staon address)
Read only
From version 02.00
Display of the acve staon address.
0x2362:007
(P511.07)
Acve EtherCAT sengs: Tx length
(EtherCAT diag.: Tx length)
Read only
From version 02.00
Display of the length of the transmied cyclic data in bytes.
0x2362:008
(P511.08)
Acve EtherCAT sengs: Rx length
(EtherCAT diag.: Rx length)
Read only
From version 02.00
Display of the length of the received cyclic data in bytes.
0x2363
(P509.00)
EtherCAT switch posion
(EtherC. switch)
Read only
From version 02.00
Display of the current rotary encoder switch sengs.
0x2368
(P516.00)
EtherCAT status
(EtherCAT status)
Read only
From version 02.00
Display of the current network status.
1 Inialisaon Network inialisaon is acve.
No PDO/SDO transmission.
Device idencaon is possible by network scan.
2 Pre-Operaonal The network is acve.
SDO transmission (CoE communicaon via mailbox) is possible.
No PDO transmission.
3 Bootstrap Firmware update acve.
For the rmware update, the FoE protocol is used.
No PDO transmission.
4 Safe-Operaonal SDO transmission (CoE communicaon via mailbox) is possible.
PDO transmission:
The input data in the process image are updated.
The output data from the process image are not transmied.
8 Operaonal Normal operaon
PDO/SDO transmission is possible.
Network synchronisaon is successful (if used).
0x2369
(P517.00)
EtherCAT error
(EtherCAT error)
Read only
From version 02.00
Bit coded display of EtherCAT errors.
Conguring the network
EtherCAT
Diagnoscs
390