18 Technical data
18.1 Standards and operang condions
18.1.1 Conformies/approvals
Conformity
CE
2014/35/EU Low-Voltage Direcve
2014/30/EU EMC Direcve (reference: CE-typical drive system)
EAC
TR CU 004/2011 Eurasian conformity: Safety of low voltage equipment
TR CU 020/2011
Eurasian conformity: Electromagnec compability of technical
means
RoHS 2011/65/EU
Restricons on the use of certain hazardous substances in electri-
cal and electronic devices
Approval
UL UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 274)
File No. E132659
18.1.2 Protecon of persons and device protecon
Degree of protecon
IP20 EN 60529
Data applies for operaonally ready mounted state and not in wire
range of terminals
NEMA 250
Only protecon against accidental contact in accordance with type
1
Open type Only in UL-approved systems
Insulaon resistance
Overvoltage category III EN 61800-5-1 0 … 2000 m amsl
Overvoltage category II EN 61800-5-1 over 2000 m amsl
Isolaon of control circuits
Safe mains isolaon via double/reinforced insula-
on
EN 61800-5-1
Protecve measures against
Short circuit
Earth fault Earth-fault protected depending on operang status
Overtemperature of motor PTC or thermal contact, I²xt monitoring
Overvoltage
Motor stalling
Leakage current
> 3.5 mA AC, > 10 mA DC EN 61800-5-1 Please observe regulaons and safety instrucons!
Starng current
≤ 3 x rated mains current
Technical data
Protecon of persons and device protecon
637