65366 0xFF56 Maximum motor frequency reached Keypad display: Max. motor freq.
Cause Error type/response Remedy
The maximum motor speed set in 0x6080
(P322.00) is acve.
The maximum output frequency of the inver-
ter has been reached.
Warning Check applicaon.
65393 0xFF71 Wrong password Keypad display: Wrong password
Cause Error type/response Remedy
A wrong password has been entered several
mes.
Warning
The blocking me for entering a password is
more than 10 seconds. (The blocking me is
doubled every me an incorrect password is
entered.)
No password can be entered as long as the
blocking me is acve.
Wait unl the blocking me has elapsed and
then enter the correct password.
Related topics
4Access protecon ^ 501
65394 0xFF72 Warning Keypad display: Warning
Cause Error type/response Remedy
Inverter is not compable with the
Controller/PLC (brand protecon).
The Controller has not wrien a deacvaon
password in the parameter yet.
The deacvaon password wrien by the
Controller is incorrect.
Warning
No response from the inverter.
The decision on whether the machine will be
commissioned or not is made by the Control-
ler.
Use corresponding (compable) OEM compo-
nents.
Related topics
4Access protecon ^ 501
65395 0xFF73 Fatal Error Keypad display: Fatal Error
Cause Error type/response Remedy
Error when reading the data from the control
unit.
Fault
Operaon of the inverter is not possible.
Switch inverter o and on again.
If the error occurs again, the manufacturer
must be contacted, since the control unit or
the device has to be replaced.
65396 0xFF74 Power unit fatal error Keypad display: PU fatal error
Cause Error type/response Remedy
Error when reading the data from the power
unit.
Fault
Operaon of the inverter is not possible.
Switch inverter o and on again.
If the error occurs again, the manufacturer
must be contacted, since the power unit or
the device has to be replaced.
65413 0xFF85 Keypad full control acve Keypad display: Keypad full ctrl
Cause Error type/response Remedy
If the "Keypad Full Control" control mode is
acve.
Warning
Both the acvity of controlling and the set-
point selecon are carried out via the key-
pad.
Clicking the CTRL keypad key stops the control
mode again.
Related topics
4Keypad full control ^ 58
Diagnoscs and fault eliminaon
Error codes, causes and remedies
636