Address Name / seng range / [default seng] Info
0x2022:013
(P700.13)
Device commands: Save parameter set 3
(Device commands: Save par. set 3)
1 = save value set 3 of the "Parameter change-over" funcon.
•
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2022:014
(P700.14)
Device commands: Save parameter set 4
(Device commands: Save par. set 4)
1 = save value set 3 of the "Parameter change-over" funcon.
•
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
14.2.4 Funcons for parameter change-over
The parameter set can be selected with the funcons "Select parameter set (bit 0)" and
"Select parameter set (bit 1)".
Details
A value set is selected in a binary-coded fashion via the triggers assigned to the two Select
parameter set (bit 0)" and " Select parameter set (bit 1)" funcons in compliance with the fol-
lowing truth table:
Select parameter set (bit 1)
0x2631:042 (P400.42)
Select parameter set (bit 0)
0x2631:041 (P400.41)
Selecon
FALSE FALSE Value set 1
FALSE TRUE Value set 2
TRUE FALSE Value set 3
TRUE TRUE Value set 4
Change-over is eected depending on the acvaon method selected in 0x4046 (P755.00)
when a state change of the selecon inputs takes place or via the trigger assigned to the
"Load parameter set" funcon.
Parameter
Address Name / seng range / [default seng] Info
0x2631:040
(P400.40)
Funcon list: Load parameter set
(Funcon list: Load param.set)
•
Seng can only be changed if the inverter is inhibi-
ted.
•
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Load parameter set" funcon.
Trigger = FALSE-TRUE edge: parameter change-over to the value set
selected via "Select parameter set (bit 0)" and "Select parameter set (bit
1)".
Trigger = FALSE: no acon.
Notes:
•
The acvaon method for the "Parameter change-over" funcon can
be selected in 0x4046 (P755.00).
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:041
(P400.41)
Funcon list: Select parameter set (bit 0)
(Funcon list: Sel. paramset b0)
•
Seng can only be changed if the inverter is inhibi-
ted.
•
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Select parameter set (bit 0)" funcon.
Selecon bit with the valency 2
0
for "Parameter change-over" funcon.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
0 Not connected No trigger assigned (trigger is constantly FALSE).
Addional funcons
Parameter change-over
Device commands for parameter change-over