17.2 Logbook
With the logbook, the controller has access to the last 32 messages of the inverter.
•
The logbook is saved persistently in the inverter.
•
The logbook has a ring buer structure:
•
As long as free memory is available in the logbook, a message is entered following the
next free memory unit.
•
When all memory units are occupied, the oldest message is deleted for a new mes-
sage.
•
Always the most recent messages remain available.
•
On the basis of the "Diag code" (32-bit word) of each individual message it can be seen
which axis the message refers to.
Parameter
Address Name / seng range / [default seng] Info
0x2022:015
(P700.15)
Device commands: Delete logbook
(Device commands: Delete logbook)
•
Seng can only be changed if the inverter is inhibi-
ted.
1 = delete all entries in the LEM logbook.
0 O / ready
1 On / start
Diagnoscs and fault eliminaon
Logbook
594