Restart or stop communicaon
The 0x2380 (P508.00) parameter can be used to restart or stop communicaon. Oponally it
is also possible to reset all communicaon parameters to the default status.
A restart of communicaon is required aer changes of the interface conguraon (e. g. sta-
on address and baud rate) in order that the changed sengs become eecve.
For restarng communicaon, there are two opons:
1.
Switch inverter o and on again.
2.
0x2380 (P508.00) Set = 1 (Restart with current values).
12.16.1.1 Restarng or stopping the communicaon
Parameter
Address Name / seng range / [default seng] Info
0x2380
(P508.00)
PROFINET communicaon
(PROFINET comm.)
•
From version 02.00
Restart / stop communicaon
•
When the device command has been executed successfully, the value
0 is shown.
0 No acon/no error Only status feedback
1 Restart with current values Restart communicaon with the current values.
2 Restart with default values Restart communicaon with the values of the PROFINET parameters that
have been saved last (0x2381:001 ... 0x2381:009).
5 Stop network communicaon Stop communicaon
10 In process Only status feedback
11 Acon cancelled
12 Fault
12.16.1.2 Device descripon le
The device descripon le must be installed in the engineering tool for conguring the net-
work (e. g. Siemens »TIA Portal«).
•
Download of GSDML les
The name of the device descripon le is as follows:
"GSDML-V<x>.<zz>-Lenze-I<NNN>PN<Version>-<yyyy><mm><dd>.xml".
Wildcard Info
x Major version of the used GSDML scheme
zz One-digit or two-digit minor version of the used GSDML scheme
NNN Specifying the inverter name, e. g. i<550>, i<950>, ...
Version First soware version that can be used with this GSDML.
yyyy Year of publicaon
mm Month of publicaon
dd Day of publicaon
Conguring the network
PROFINET
Commissioning
483