13.2.1 Congure reset behaviour
Customers who use DIP switches for their IP address/baud conguraon will lose them when
they load the default seng. 0x2022:001 (P700.01)
For some customers, it is a common method to always have the same starng condions for
the parameters.
With this funcon, a user can load and congure the default seng acon. 0x2022:001
(P700.01)
Details
By default, all parameters are reset when the default sengs are loaded.0x2022:001
(P700.01)
The user has the opon of reconguring this funcon. 0x2024:001 This allows certain parame-
ter groups to be excluded.
The following cannot be selected for the reset: address of the communicaon bus, the data
format, the baud rate, the subnet mask, and for WLAN, channel, security, network password
and SSID name. Their conguraon values will be retained.
Note that before restoring default sengs, the parameter 0x2024:001 must have its bit set
from 0 to 1 so that the eldbus parameters are excluded from the reset.
Note that the purpose of this funcon is to enable the master to restore the connecon to an
inverter aer loading the default sengs. Because all data mapping and funconal sengs
are reset, the user must let the master recongure the sengs of the inverter before it oper-
ates the inverter.
Parameter
Address Name / seng range / [default seng] Info
0x2024:001 Special sengs: Congure default seng
0 ... [0] ... 65535
By default, all parameters are reset when the default sengs are loaded
(0x2022: 001). The user has the opon of reconguring this funcon
with the parameter. This allows certain parameter groups to be exclu-
ded.
Bit 0 Exclude network TRUE: Exclusion of the network parameters (address of the communica-
on bus, the data format, the baud rate, the subnet mask, and for
WLAN, channel, security, network password and SSID name).
Device funcons
Reset parameters to default
Congure reset behaviour