10.7.6 Motor control sengs
Aer the motor sengs have been made, the dierent control loops must be set. For a quick
commissioning, the calculaons and sengs are made automacally if one of the following
opmisaons is carried out:
4Select motor from motor catalogue ^ 51
4Automac motor idencaon (energized) ^ 216
4Automac motor calibraon (non-energized) ^ 218
Details
The following controllers have an inuence in the respecve motor control type:
Controller Motor control type
VFC open
loop
VFC closed
loop
SC-ASM SL-PSM SLVC
Speed controller ^ 223
l l l
Current controller ^ 224
l l l l l
ASM eld controller ^ 224
l
l
ASM eld weakening controller ^ 224
l
l
Imax controller ^ 226
l l
Flying restart controller ^ 227
l
l l
SLVC controller ^ 227
l
Slip controller ^ 227
l
VFC open loop
VFC closed loop
SC-ASM
SL-PSM
SLVC
= V/f characterisc control
= V/f characterisc control with speed feedback
= servo control for asynchronous motor
= sensorless control for synchronous motor
= sensorless vector control
Conguring the motor control
Opons for opmising the control loops
Motor control sengs
222