8.1.4 Ramp me
Parameter
Address Name / seng range / [default seng] Info
0x2948:002
(P336.02)
Torque setpoint: ramp me
(Torque setpoint: Ramp me)
0.0 ... [1.0] ... 60.0 s
From version 03.00
Ramp me for operang mode "MS: Torque mode".
The torque setpoint is led via a ramp generator. This provides for a
"smooth" switch-over between dierent setpoint sources.
The set ramp me refers to the ramping up/down of 0 ... 100 % rated
motor torque 0x6076 (P325.00). At a lower setpoint selecon, the
ramp me is reduced accordingly.
Conguring the torque control
Basic seng
Ramp me