18.3 1-phase mains connecon 230/240 V
18.3.1 Rated data
The output currents apply to these operang condions:
•
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
•
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter I55AE125B I55AE125D I55AE137B I55AE137D I55AE155B I55AE155D
Rated power kW 0.25 0.25 0.37 0.37 0.55 0.55
Rated power hp 0.33 0.33 0.5 0.5 0.75 0.75
Mains voltage range 1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
Without mains choke A 4 4 5.7 5.7 7.6 7.6
With mains choke A 3.6 3.6 4.8 4.8 7.1 7.1
Apparent output power kVA 0.6 0.6 0.9 0.9 1.2 1.2
Rated output current
2 kHz A - - - - 3.2 3.2
4 kHz A 1.7 1.7 2.4 2.4 3.2 3.2
8 kHz A 1.7 1.7 2.4 2.4 3.2 3.2
16 kHz A 1.1 1.1 1.6 1.6 2.1 2.1
Power loss
2 kHz W - - - - 22 22
4 kHz W 15 15 18 18 23 23
8 kHz W 15 15 20 20 25 25
16 kHz W 19 19 24 24 30 30
For controller inhibit W 6 6 6 6 6 6
Cyclic mains switching 3 mes per minute
Max. Motor cable length shielded
Without EMC category m 50 50 50 50 50 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m 3 - 3 - 3 -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m 15 - 15 - 20 -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m 15 - 15 - 50 -
Weight kg 0.8 0.8 0.8 0.8 1 1
Weight lb 1.8 1.8 1.8 1.8 2.2 2.2
Technical data
1-phase mains connecon 230/240 V
Rated data
640