4.3.1 Keypad
The keypad is an easy means for the local operaon, parameterisaon, and diagnoscs of the
inverter.
•
The keypad is simply connected to the diagnosc interface on the front of the inverter.
•
The keypad can also be connected and removed during operaon.
Funcon of keypad keys in operang mode
Key Actuaon Condion Acon
Shortly Local keypad control acve.
Display "LOC"
Run motor.
Remote control acve
Display "REM"
Display "KSTOP"
Deacvate keypad triggered stop.
The motor remains at standsll.
Display changes from "KSTOP" to "STOP".
Shortly No Jog operaon Stop motor.
Display "KSTOP"
Shortly Operang mode Change to parameterisaon mode.
4Keypad parameterisaon mode ^ 554
Longer than 3 s None (anyme possible) Save parameter sengs in the user memory of the memory
module.
Shortly During operaon Scroll through informaon in the above status line.
Shortly Manual setpoint selecon via keypad
acve.
Display "MAN"
Change frequency setpoint.
Shortly Operang mode Acvate full keypad control
Display "ON?" à Conrm with
Control and setpoint selecon can now only be carried out via
keypad.
Renewed clicking: Exit full keypad control.
Display "OFF?" à Conrm with
4Keypad full control ^ 58
Shortly Local keypad control acve.
Display "LOC"
Reversal of rotaon direcon.
Display "REV?" à Conrm with
4Congure R/F and CTRL keys ^ 581
The Lenze Smart Keypad app can be found in the Google Play Store or in the Apple App Store.
Android
iOS
Commissioning
Operang interfaces
Keypad
25