12.14.2 Basic seng and opons
Each network node must be provided with a unique node address (node ID).
Seng the node address
The node address can be set in 0x23C1:004 or via the two rotary encoder switches on the
front of the inverter.
•
If both rotary encoder switches are set to "0", the value set in 0x23C1:004 is used as node
address.
•
The seng that is acve when the inverter is switched on is the eecve seng.
•
A value changed during operaon only gets valid when the device is restarted.
•
Valid node addresses for controlled nodes: 1 ... 239
•
The resulng IP address is "192.168.100.[node address]".
Example: Seng of the node address 52 via the rotary encoder switches
•
52 = 3 x 16 + 4 x 1
•
The resulng IP address is "192.168.100.52".
Note: If the value set via the rotary encoder switches is higher than 239, the node address is
set to 239.
Diagnosc parameters:
•
0x23C2:004 displays the acve node address.
•
0x23C3 displays the switch seng at the last mains switching.
Parameter
Address Name / seng range / [default seng] Info
0x1006 NMT_CycleLen_U32
0 ... [0] ... 4294967295
•
From version 05.00
Length of the POWERLINK cycle in μs.
•
The selected value must correspond to the real bus cycle me in order
that the internal monitoring modes operate correctly.
•
In the congured state, all POWERLINK nodes must be set to an iden-
cal value.
0x1F98:007 NMT_CycleTiming_REC: MulpleCycleCnt_U8
0 ... [0] ... 255
•
From version 05.00
Seng of the maximum number of mulplexed cycles.
•
In case of the seng "3", the mulplexed cycle is repeated every 3
cycles.
•
Within one mulplexed cycle, the nodes are queried according to the
values in 0x1F9B:xxx. If, for instance, the value "2" is entered for a
node in 0x1F9B:xxx, it is always only queried in the 2nd of 3 mul-
plexed cycles.
0x1F98:009 NMT_CycleTiming_REC: Prescaler_U16
0 ... [2] ... 1000
•
From version 05.00
Conguraon of the switching rate of the SoC-PS ag.
0x1F99 NMT_CNBasicEthernetTimeout_u32
0 ... [0] ... 4294967295
•
From version 05.00
Seng of the maximum me the boong controlled node waits for the
managing node.
•
If the controlled node detects a managing node within the me, the
controlled node changes to the "NMT_CS_PREOPERATIONAL_1" state.
Otherwise, the controlled node changes to the "Basic Ethernet Mode"
state.
0x1F9A NMT_HostName_VSTR
•
From version 05.00
Seng of a DNS-compable device name.
•
The length is limited to 20 characters.
•
The device name must be clear within the network domain.
•
The device name starts with a leer ends with a leer or a number.
Permied characters:
•
Leer (A ... Z, a ... z)
•
Numbers (0 ... 9)
•
Hyphen (-)
Conguring the network
POWERLINK
Basic seng and opons
446