Parameterisaon sequence
As soon as the parameterisaon has been started, the following steps are iniated by the
engineering tool:
1.The motor rang data and the motor equivalent circuit diagram data are loaded from the
motor catalogue.
2.The motor controller sengs and the speed controller sengs are automacally calculated
based on the previously loaded data.
Notes:
The data involved in this parameterisaon are provided be the motor catalogue alone. Fur-
ther user data is not required.
The inverter characterisc is not changed by this opmisaon.
Parameter
Address Name / seng range / [default seng] Info
0x2C01:010 Motor parameters: Motor name The name (e.g. " 1") can be freely selected by the user.
If the motor in the engineering tool has been selected from the "motor
catalog", the respecve motor name is automacally entered here
(example: "MDSKA080-22, 70").
5.8.2 Manual seng of the motor data
Manually set the motor data in accordance with the manufacturer's informaon / motor data
sheet in the following parameters, provided that an externally supplied motor is connected to
the inverter.
Parameter
Address Name / seng range / [default seng] Info
0x2910:001
(P335.01)
Motor moment of inera
(Motor inera)
0.00 ... [3.70]* ... 20000000.00 kg cm²
* Default seng depending on the size.
Seng of the moment of inera of the motor, relang to the motor.
0x2C01:001 Motor parameters: Number of pole pairs
Read only
Display of the number of pole pairs calculated from the rated speed and
rated frequency.
0x2C01:002 Motor parameters: Stator resistance
0.0000 ... [10.1565]* ... 125.0000 Ω
* Default seng depending on the size.
General motor data.
Carry out sengs as specied by manufacturer data/motor data sheet.
Note!
When you enter the motor nameplate data, take into account the phase
connecon implemented for the motor (star or delta connecon). Only
enter the data applying to the connecon type selected.
0x2C01:003 Motor parameters: Stator leakage inductance
0.000 ... [23.566]* ... 500.000 mH
* Default seng depending on the size.
0x2C01:004
(P320.04)
Motor parameters: Rated speed
(Motor parameters: Rated speed)
Device for 50-Hz mains: 50 ... [1450] ... 50000 rpm
Device for 60-Hz mains: 50 ... [1750] ... 50000 rpm
General motor data.
Carry out sengs as specied by motor nameplate data.
Note!
When you enter the motor nameplate data, take into account the phase
connecon implemented for the motor (star or delta connecon). Only
enter the data applying to the connecon type selected.
0x2C01:005
(P320.05)
Motor parameters: Rated frequency
(Motor parameters: Rated frequency)
Device for 50-Hz mains: 1.0 ... [50.0] ... 1000.0 Hz
Device for 60-Hz mains: 1.0 ... [60.0] ... 1000.0 Hz
0x2C01:006
(P320.06)
Motor parameters: Rated power
(Motor parameters: Rated power)
0.00 ... [0.25]* ... 655.35 kW
* Default seng depending on the size.
0x2C01:007
(P320.07)
Motor parameters: Rated voltage
(Motor parameters: Rated voltage)
0 ... [230]* ... 65535 V
* Default seng depending on the size.
0x2C01:008
(P320.08)
Motor parameters: Cosine phi
(Motor parameters: Cosine phi)
0.00 ... [0.80] ... 1.00
0x2C02:003
(P351.03)
Motor parameter (ASM): Magnesing current
(ASM motor par.: Magn. current)
0.00 ... [0.96]* ... 500.00 A
* Default seng depending on the size.
Equivalent circuit data required for the motor model of the asynchro-
nous machine.
Basic seng
Motor data
Select motor from motor catalogue
52