12.6.6.1 Not ready to switch on
This is the device state of the inverter directly aer switching on the supply voltage.
In this device status, the device is inialised.
Communicaon is not possible yet.
The inverter cannot be parameterised yet and no device commands can be carried out yet.
The motor brake, if available, is closed.
Operaon is inhibited.
Mains on
Quick stop active
Switch-on inhibited
Fault
Fault reaction
active
Operation enabled
Switched on
Not ready
to switch on
Ready to switch on
1 From all states
2 Power secon inhibited (pulse inhibit)
3 Power secon enabled
Bit paern in the CiA 402 status word (0x6041 (P780.00))
Bit 15 ... 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
(specic)
Warning
acve
Operaon
inhibited
Quick stop
acve
DC bus ready
for operaon
Fault acve Operaon
enabled
Switched on Ready to
switch on
X X 0 X X 0 0 0 0