Address Name / seng range / [default seng] Info
0x400E:015
(P505.15)
NetWordIN1 funcon: Bit 14
(NetWordIN1 fct.: NetWordIN1.14)
Seng can only be changed if the inverter is inhibi-
ted.
For further possible sengs, see parameter
0x400E:001 (P505.01). ^ 286
Denion of the funcon that is to be triggered via bit 14 of the mappa-
ble NetWordIN1 data word.
0 Not acve Trigger bit without any funcon.
0x400E:016
(P505.16)
NetWordIN1 funcon: Bit 15
(NetWordIN1 fct.: NetWordIN1.15)
Seng can only be changed if the inverter is inhibi-
ted.
For further possible sengs, see parameter
0x400E:001 (P505.01). ^ 286
Denion of the funcon that is to be triggered via bit 15 of the mappa-
ble NetWordIN1 data word.
0 Not acve Trigger bit without any funcon.
12.1.4 Dene your own status word format
The mappable data word NetWordOUT1 is available for implemenng a separate status word
format.
Details
Designaon Parameter Associated mapping
entry *
Further informaon
NetWordOUT1 0x400A:001 (P591.01) 0x400A0110 The triggers for bits 0 ... 15 of the NetWordOUT1 data word are dened
in 0x2634:010 (P420.10) ... 0x2634:025 (P420.25).
* A mapping entry consists of index, subindex and data length in bits of the parameter to be mapped.
General informaon about the process of data mapping can be found in the chapter of the
same name for the corresponding network.
Parameter
Address Name / seng range / [default seng] Info
0x2634:010
(P420.10)
Digital outputs funcon: NetWordOUT1 - bit 0
(Dig.out.funcon: NetWordOUT1.00)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 0 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
51 Ready for operaon TRUE if inverter is ready for operaon (no error acve, no STO acve and
DC-bus voltage ok). Otherwise FALSE.
0x2634:011
(P420.11)
Digital outputs funcon: NetWordOUT1 - bit 1
(Dig.out.funcon: NetWordOUT1.01)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 1 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2634:012
(P420.12)
Digital outputs funcon: NetWordOUT1 - bit 2
(Dig.out.funcon: NetWordOUT1.02)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 2 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
52 Operaon enabled TRUE if inverter and start are enabled. Otherwise FALSE.
0x2634:013
(P420.13)
Digital outputs funcon: NetWordOUT1 - bit 3
(Dig.out.funcon: NetWordOUT1.03)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 3 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
56 Fault acve TRUE if error is acve. Otherwise FALSE.
0x2634:014
(P420.14)
Digital outputs funcon: NetWordOUT1 - bit 4
(Dig.out.funcon: NetWordOUT1.04)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 4 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2634:015
(P420.15)
Digital outputs funcon: NetWordOUT1 - bit 5
(Dig.out.funcon: NetWordOUT1.05)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 263
Assignment of a trigger to bit 5 of NetWordOUT1.
Trigger = FALSE: bit set to 0.
Trigger = TRUE: bit set to 1.
54 Quick stop acve TRUE if quick stop is acve. Otherwise FALSE.
Conguring the network
Control the inverter via network
Dene your own control word format
292