12.13.5 Diagnoscs
12.13.5.1 LED status display
Informaon on the CIP status can be obtained quickly via the "MS" and "NS" LED displays on
the front of the inverter. In addion, the LEDs at the RJ45 sockets indicate the connecon sta-
tus.
The meaning of the "MS" and "NS" LEDs can be obtained from the following two tables.
LED "MS" (green/red) Module status Status/meaning
o Nonexistent The network opon is not supplied with voltage.
On (green)
Operaonal The network opon works correctly.
Blinking green
Standby The network opon is not congured completely or the conguraon is incorrect.
Blinking red
Major recoverable
fault
The network opon contains a correctable error.
on (red)
Major unrecoverable
fault
The network opon contains a non-correctable error.
Blinking green/red
Device self tesng The network opon executes a self-test.
LED "NS" (green/red) Network status Status/meaning
o No IP address The network opon is not supplied with voltage or has not received an IP address yet.
On (green)
Connected The network opon works correctly an has established a connecon to the master.
Blinking green
No connecons The network opon
•
works correctly,
•
has been assigned to an IP address,
•
has not been implemented into the network yet by the master.
Blinking red
Connecon meout A me-out has occurred.
on (red)
Duplicate IP The network opon cannot access the network (IP address conict).
Blinking green/red
Device self tesng The network opon executes a self-test.
Status displays at the RJ45 sockets
The LEDs at the RJ45 sockets indicate the connecon status to the network:
LED "Link" (green) Status/meaning
o No connecon to the network.
on
A physical connecon to the network is available.
LED "Acvity" (yellow) Status/meaning
o No data transfer.
on or ickers
Data is exchanged via the network.
12.13.5.2 Informaon on the network
The following parameters serve to diagnose the communicaon acvies between the inver-
ter and the Modbus network.
The following parameters show informaon on the network.
Parameter
Address Name / seng range / [default seng] Info
0x23B2:001
(P511.01)
Acve Modbus TCP sengs: Acve IP address
(Act. MBTCP se.: Act. IP address)
•
Read only
•
From version 04.00
Display of the acve IP address.
Conguring the network
Modbus TCP
Diagnoscs
441