Address Name / seng range / [default seng] Info
0x1F93:002 NMT_EPLNodeID_REC: NodeIDByHW_BOOL
Read only
From version 05.00
Display whether the node address (node ID) has been set via rotary
encoder switch or via soware.
0x1F98:001 NMT_CycleTiming_REC: IsochrTxMaxPayload_ U16
Read only
From version 05.00
Display of the size of the isochronous transmit memory.
0x1F98:002 NMT_CycleTiming_REC: IsochrRxMaxPayload_ U16
Read only
From version 05.00
Display of the size of the isochronous receive memory.
0x1F98:003 NMT_CycleTiming_REC: PResMaxLatency_U32
Read only: x ns
From version 05.00
Display of the isochronous response delay.
0x23C2:001 Acve POWERLINK sengs: IP address
Read only
From version 05.00
Display of the acve IP address.
0x23C2:002 Acve POWERLINK sengs: Subnet
Read only
From version 05.00
Display of the acve subnet mask.
0x23C2:003 Acve POWERLINK sengs: Gateway
Read only
From version 05.00
Display of the IP address of the router that connects the POWERLINK
segment to the higher-level network.
0x23C2:004 Acve POWERLINK sengs: Node ID
Read only
From version 05.00
Display of the acve node address (node ID) in the network.
0x23C2:005 Acve POWERLINK sengs: MAC Address
Read only
From version 05.00
Display of the acve MAC address.
0x23C2:007 Acve POWERLINK sengs: Tx length
Read only
From version 05.00
Display of the length of the transmied cyclic data in bytes.
0x23C2:008 Acve POWERLINK sengs: Rx length
Read only
From version 05.00
Display of the length of the received cyclic data in bytes.
0x23C3 POWERLINK switch posion
Read only
From version 05.00
Display of the rotary encoder switch seng at the last mains power-on.
0x23C8:001 POWERLINK status: Network management
Read only
From version 05.00
Display of the current bus status.
9 NMT_CS_INITIALISATION
28 NMT_CS_NOT_ACTIVE
29 NMT_CS_PRE_OPERATIONAL_1
30 NMT_CS_BASIC_ETHERNET
77 NMT_CS_STOPPED
93 NMT_CS_PRE_OPERATIONAL_2
109 NMT_CS_READY_TO_OPERATE
253 NMT_CS_OPERATIONAL
0x23C9:001 POWERLINK error: Acvaon
Read only
From version 05.00
Bit coded display of the bus error state reported by the LED "BE" (Bus
Error).
Bit 0 = 0 (0x0000) ≡ no bus error
Bit 0 = 1 (0x0001) ≡ acve bus error
0 Deacvated
1 Acvated
12.14.6.3 Informaon on the Ethernet interface
Parameter
Address Name / seng range / [default seng] Info
0x1030:001 NMT_InterfaceGroup_0h_REC: InterfaceIndex_U16
Read only
From version 05.00
Display of the interface number of the Ethernet interface.
Conguring the network
POWERLINK
Diagnoscs
452

Table of Contents

Other manuals for Lenze i550