13.2 Reset parameters to default
With the "Load default sengs" device command, all parameters can be reset to the default
seng.
By execung this device command, all parameter sengs made by the user are
lost!
Details
All current parameters in the RAM memory of the inverter are overwrien by the default
parameters stored in the rmware of the inverter. (The persistent parameters in the mem-
ory module remain unaected by this measure.)
0x2022 001:
Inverter
Load
RAM
memory
Firmware
Parameter
default setting
Aerwards the inverter can be parameterised again on the basis of this inial state.
Typical applicaon: incorrect or unknown parameter sengs.
The device command only has an eect on the RAM. For a permanent acceptance of the
changes made, the data must subsequently be saved in the memory module. 4Saving/
loading the parameter sengs^ 498
Parameter
Address Name / seng range / [default seng] Info
0x2022:001
(P700.01)
Device commands: Load default sengs
(Device commands: Load def. se.)
Seng can only be changed if the inverter is inhibi-
ted.
1 ≡ reset all parameters in the RAM memory of the inverter to the
default seng that is stored in the inverter rmware.
All parameter changes made by the user are lost during this process!
It may take some seconds to execute the task. When the task has
been executed successfully, the value 0 is shown.
Loading parameters has a direct eect on the cyclic communicaon:
The data exchange for control is interrupted and a communicaon
error is generated.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
Device funcons
Reset parameters to default