18.4 3-phase mains connecon 230/240 V
18.4.1 Rated data
The output currents apply to these operang condions:
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter I55AE125D I55AE137D I55AE155D I55AE175D I55AE211D I55AE215D
Rated power kW 0.25 0.37 0.55 0.75 1.1 1.5
Rated power hp 0.33 0.5 0.75 1 1.5 2
Mains voltage range 3/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0-230/240 V
Rated mains current
Without mains choke A 2.6 3.9 4.8 6.4 7.8 9.5
With mains choke A 2 3 3.8 5.1 5.6 6.8
Apparent output power kVA 0.6 0.9 1.2 1.6 2.2 2.6
Rated output current
2 kHz A - - 3.2 4.2 6 7
4 kHz A 1.7 2.4 3.2 4.2 6 7
8 kHz A 1.7 2.4 3.2 4.2 6 7
16 kHz A 1.1 1.6 2.1 2.8 4 4.7
Power loss
2 kHz W - - 22 27 36 41
4 kHz W 15 18 23 29 37 43
8 kHz W 15 20 25 33 42 50
16 kHz W 19 24 30 38 51 59
For controller inhibit W 6 6 6 6 6 6
Cyclic mains switching 3 mes per minute
Max. Motor cable length shielded
Without EMC category m 50 50 50 50 50 50
Category C1 (2 kHz, 4 kHz, 8
kHz)
m - - - - - -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m - - - - - -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m - - - - - -
Weight kg 0.8 0.8 1 1 1.35 1.35
Weight lb 1.8 1.8 2.2 2.2 3 3
Technical data
3-phase mains connecon 230/240 V
Rated data