Address Name / seng range / [default seng] Info
0x2022:008
(P700.08)
Device commands: Load parameter set 2
(Device commands: Load par. set 2)
1 = load value set 2 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4043/1...32.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2022:009
(P700.09)
Device commands: Load parameter set 3
(Device commands: Load par. set 3)
1 = load value set 3 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4044/1...32.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2022:010
(P700.10)
Device commands: Load parameter set 4
(Device commands: Load par. set 4)
1 = load value set 4 of the "Parameter change-over" funcon.
The parameters specied in 0x4041/1...32 are set to the values set in
0x4045/1...32.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2022:011
(P700.11)
Device commands: Save parameter set 1
(Device commands: Save par. set 1)
1 = save value set 1 of the "Parameter change-over" funcon.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
0x2022:012
(P700.12)
Device commands: Save parameter set 2
(Device commands: Save par. set 2)
1 = save value set 2 of the "Parameter change-over" funcon.
When the device command has been executed successfully, the value
0 is shown.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
Addional funcons
Parameter change-over
Device commands for parameter change-over
529