Address Name / seng range / [default seng] Info
101 Sequence acve (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is running and is currently not suspended.
4Sequencer ^ 91
102 Sequence suspended (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is currently suspended.
4Sequencer ^ 91
103 Sequence done (from version 03.00) Status signal of the "sequencer" funcon:
TRUE if the sequence is completed (nal segment has been passed
through).
4Sequencer ^ 91
104 Local control acve TRUE if local keypad control ("LOC") acve. Otherwise FALSE.
105 Remote control acve TRUE if remote control ("REM") via terminals, network, etc. acve. Oth-
erwise FALSE.
106 Manual setpoint selecon acve TRUE if manual setpoint selecon ("MAN") via keypad acve. Otherwise
FALSE.
Selecon of the trigger for the "Acvate keypad setpoint" funcon in
0x2631:016 (P400.16).
107 Automac setpoint selecon acve TRUE if automac setpoint selecon ("AUTO") via terminals, network,
etc. acve. Otherwise FALSE.
108 Parameter set 1 acve TRUE if parameter set 1 is loaded and acve. Otherwise FALSE.
109 Parameter set 2 acve TRUE if parameter set 2 is loaded and acve. Otherwise FALSE.
110 Parameter set 3 acve TRUE if parameter set 3 is loaded and acve. Otherwise FALSE.
111 Parameter set 4 acve TRUE if parameter set 4 is loaded and acve. Otherwise FALSE.
112 Parameter set load OK TRUE aer any parameter set has been loaded. Otherwise FALSE.
113 Parameter set load fail TRUE if any of the parameter sets could not be loaded. Otherwise FALSE.
115 Release holding brake Trigger signal for releasing the holding brake (TRUE = release holding
brake).
Note!
If this trigger is assigned to the relay or a digital output, the deceleraon
mes set for the respecve output are not eecve (are internally set to
"0"). Only the deceleraon me set in 0x2820:012 (P712.12) for closing
the holding brake inuences in this case the me-dependent behaviour
of the output.
4Holding brake control^ 203
117 Motor phase failure TRUE if a motor phase failure has been detected. Otherwise FALSE.
4Motor phase failure detecon ^ 236
118 UPS operaon acve TRUE if UPS operaon is acve. Otherwise FALSE.
4EOperaon with UPS ^ 545
155 STO acve TRUE if the integrated safety system has triggered the "Safe torque o
(STO)" funcon and if the safe inputs SIA and SIB = LOW (simultane-
ously). Otherwise FALSE.
4Safe Torque O (STO)^ 548
201 Internal value Internal values of the manufacturer.
202 Internal value
203 Internal value
204 Internal value
205 Internal value
206 Internal value
0x2635:001
(P421.01)
Inversion of digital outputs: Relay
(DO inversion: Relay inverted)
Relay inversion
0 Not inverted
1 Inverted
0x4018:003 Relay: Switch-o delay
0.000 ... [0.000] ... 65.535 s
Switch-o delay for the relay.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the decelera-
on me set in 0x2820:012 (P712.12)for closing the holding brake inu-
ences the me-dependent behaviour of the relay.
I/O extensions and control connecons
Congure digital outputs
Relay output
266