EasyManua.ls Logo

Lenze i550

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Name / seng range / [default seng] Info
0x2631:018
(P400.18)
Funcon list: Acvate preset (bit 0)
(Funcon list: Setp: Preset b0)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate preset (bit 0)" funcon.
The bit with the valency 2
0
for bit-coded selecon and the acvaon of a
parameterised setpoint (preset).
Trigger = FALSE: bit = "0".
Trigger = TRUE: bit = "1".
14 Digital input 4 State of X3/DI4, taking an inversion set in 0x2632:004 (P411.04) into
consideraon.
0x2631:019
(P400.19)
Funcon list: Acvate preset (bit 1)
(Funcon list: Setp: Preset b1)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate preset (bit 1)" funcon.
The bit with the valency 2
1
for bit-coded selecon and the acvaon of a
parameterised setpoint (preset).
Trigger = FALSE: bit = "0".
Trigger = TRUE: bit = "1".
15 Digital input 5 State of X3/DI5, taking an inversion set in 0x2632:005 (P411.05) into
consideraon.
0x2631:020
(P400.20)
Funcon list: Acvate preset (bit 2)
(Funcon list: Setp: Preset b2)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate preset (bit 2)" funcon.
The bit with the valency 2
2
for bit-coded selecon and the acvaon of a
parameterised setpoint (preset).
Trigger = FALSE: bit = "0".
Trigger = TRUE: bit = "1".
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:021
(P400.21)
Funcon list: Acvate preset (bit 3)
(Funcon list: Setp: Preset b3)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate preset (bit 3)" funcon.
Selecon bit with the valency 2
3
for the bit-coded selecon and acva-
on of a parameterised setpoint (preset value).
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:022
(P400.22)
Funcon list: Acvate setpoint via HTL input
(Funcon list: Setp: HTL input)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate setpoint via HTL input" func-
on.
Trigger = TRUE: HTL input is used as setpoint source (if the trigger
assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:025
(P400.25)
Funcon list: Acvate MOP setpoint
(Funcon list: Setp: MOP)
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate MOP setpoint" funcon.
Trigger = TRUE: the "Motor potenometer" funcon is used as setpoint
source (if the trigger assigned has the highest setpoint priority).
Trigger = FALSE: no acon / deacvate funcon again.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:026
(P400.26)
Acvate segment setpoint (bit 0)
(Setp: Segment b0)
From version 03.00
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate segment setpoint (bit 0)" func-
on.
Selecon bit with the valency 20 for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:027
(P400.27)
Acvate segment setpoint (bit 1)
(Setp: Segment b1)
From version 03.00
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate segment setpoint (bit 1)" func-
on.
Selecon bit with the valency 2
1
for the bit-coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
Conguring the frequency control
Changing the setpoint source during operaon
132