Address Name / seng range / [default seng] Info
0x2631:028
(P400.28)
Acvate segment setpoint (bit 2)
(Setp: Segment b2)
From version 03.00
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate segment setpoint (bit 2)" func-
on.
Selecon bit with the valency 2
2
for the bit coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:029
(P400.29)
Acvate segment setpoint´(bit 3)
(Setp: Segment b3)
From version 03.00
Further seng opons: 4Trigger list ^ 64
Assignment of a trigger for the "Acvate segment setpoint´(bit 3)" func-
on.
Selecon bit with the valency 2
3
for the bit coded selecon and acva-
on of a parameterised segment setpoint.
Trigger = FALSE: selecon bit = "0".
Trigger = TRUE: selecon bit = "1".
Notes:
During normal operaon (no acve sequence), this funcon serves to
acvate the setpoint of a segment (instead of an enre sequence in
the sequencer operaon).
This funcon is not intended for the use in the sequencer operaon.
0 Not connected No trigger assigned (trigger is constantly FALSE).
Conguring the frequency control
Changing the setpoint source during operaon
133