The default seng "Flexible I/O conguraon [0]" in 0x2824 (P200.00) enables a exible
control of the inverter via digital inputs, network and keypad. The control of the inverter
via the digital inputs is precongured. For details see the subchapter "Flexible I/O congu-
raon". ^ 56
For details of the network control of the inverter, see the chapter "Control the inverter via
network". ^ 281
If the keypad is to be used as the control source for the applicaon, set "Keypad [1]" in
0x2824 (P200.00). For details, see subchapter "Keypad control". ^ 57
The control source that is currently acve is displayed in 0x282B:001 (P125.01).
Parameter
Address Name / seng range / [default seng] Info
0x2824
(P200.00)
Control selecon
(Control select.)
Selecon of the type of inverter control.
0 Flexible I/O conguraon This selecon enables a exible assignment of the start, stop, and rotat-
ing direcon commands with digital signal sources.
Digital signal sources can be digital inputs, network and keypad.
The I/O conguraon is made via the parameters 0x2631:xx (P400.xx).
1 Keypad This selecon enables the motor to be started exclusively via the start
key of the keypad. Other signal sources for starng the motor are
ignored.
Start motor Stop motor
Note!
The funcons "Enable inverter" 0x2631:001 (P400.01) and "Run"
0x2631:002 (P400.02) must be set to TRUE to start the motor.
If jog operaon is acve, the motor cannot be stopped via the
keypad key.
Start, stop and rotang direcon commands
Control selecon
55