EasyManua.ls Logo

Lenze i550

Lenze i550
704 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Name / seng range / [default seng] Info
0x282A:004 Status words: Extended status word
Read only
Bit-coded status word.
Bit 8 Reverse rotaonal direcon 1 ≡ reversal acve.
Bit 10 Inverter disabled (safety) 1= the inverter has been disabled by the integrated safety system.
Bit 11 STO acve 1 = "Safe torque o (STO)" funcon has been triggered by the integrated
safety system. Safe inputs SIA and SIB = LOW (simultaneously).
0x282A:005
(P126.05)
Status words: Device status
(Status words: Device status)
Read only
Display of the current inverter device state.
0 Inialisaon
2 Not ready to switch on
3 Switch on disabled
4 Ready to switch on
5 Switched on
6 Operaon enabled
7 Disable operaon
8 Shut down
9 Quick stop acve
10 Fault reacon acve
11 Fault
0x282B:001
(P125.01)
Inverter diagnoscs: Acve control source
(Inverter diag.: Acve control)
Read only
Display of the control source that is currently acve.
0 Flexible I/O conguraon
1 Network
2 Keypad
8 Keypad full control
9 Manual mode
0x282B:002
(P125.02)
Inverter diagnoscs: Acve setpoint source
(Inverter diag.: Acve setpoint)
Read only
Display of the setpoint source that is currently acve.
0 Not selected
1 Analog input 1
2 Analog input 2
3 Keypad Setpoint
4 HTL input
5 Network Setpoint
9 Manual mode: setpoint
Diagnoscs and fault eliminaon
Diagnosc parameters
Inverter diagnoscs
601