t
0 Hz
30 Hz
10 Hz
20 Hz
40 Hz
50 Hz
60 Hz
-40 Hz
-60 Hz
-50 Hz
-30 Hz
-20 Hz
-10 Hz
t
t
t
t
t
t
t
t
t
85 kHz < 10 kHz 55 kHz
0x2641:002
55 kHz
0x2DDD
PTO1 < 10 kHz
Specification of direction via DI3
Monitoring of HTL input
Digital input 1 [11]
Run
Constant TRUE [1]
Stop active [53]
Rotational direction reversed [69]
Warning [58]
Running [50]
Output signals
Status signals
Output frequency
Enable inverter
Input signals
Pulse train via DI4
FunctionTrigger
The status signals can be assigned to digital outputs. 4Congure digital outputs ^ 263
①
If the inverter is enabled and no error is acve, the motor can be started with the "Run" funcon.
The motor follows the pulse train according to the set input and seng range.
②
The "counter-clockwise (CCW)" direcon of rotaon is requested externally (Controller; PTO2) via digital input DI3.
③
If the pulse train signal falls below the input frequency of 10 kHz, for longer than 2 s, a warning is output.
④
If "Run" is set to FALSE, the motor is stopped with the stop method set in 0x2838:003 (P203.03). In the example: Stop with standard ramp.
I/O extensions and control connecons
Congure digital inputs
Congure digital inputs DI3/DI4 for detecng a pulse train
254