Address Name / seng range / [default seng] Info
0x2644:003
(P423.03)
DO1 frequency setup: Funcon
(DO1 freq. setup: Funcon)
•
From version 05.00
Selecon of the signal to be provided at the digital output 1 as pulse
train.
0 Not connected No pulse train signal is output at the digital output 1.
•
The digital output 1 is congured as "normal" digital output.
•
The digital output 1 is controlled with the trigger selected in
0x2634:002 (P420.02).
1 Output frequency Actual output frequency (resoluon: 0.1 Hz).
2 Frequency setpoint Current frequency setpoint (resoluon: 0.1 Hz).
3 Analog input 1 Input signal of analog input 1 (resoluon: 0.1 %).
4 Analog input 2 Input signal of analog input 2 (resoluon: 0.1 %).
5 Motor current Actual motor current (resoluon: 0.1 A).
6 Output power Actual output power (resoluon: 0.001 kW).
7 Actual torque Torque actual value (resoluon: 0.1 %).
•
100 % ≡ permissible maximum torque 0x6072 (P326.00)
20 NetWordIN3 Actual value of the NetWordIN3 data word (resoluon: 0.1 %).
4Process input data^ 302
21 NetWordIN4 Actual value of the NetWordIN4 data word (resoluon: 0.1 %).
4Process input data^ 302
0x2644:004
(P423.04)
DO1 frequency setup: Minimum signal
(DO1 freq. setup: Min. signal)
-2147483648 ... [0] ... 2147483647
•
From version 05.00
Denion of the signal value that corresponds to the Minimum fre-
quency at the digital output 1.
0x2644:005
(P423.05)
DO1 frequency setup: Maximum signal
(DO1 freq. setup: Max. signal)
-2147483648 ... [1000] ... 2147483647
•
From version 05.00
Denion of the signal value that corresponds to the maximum fre-
quency at the digital output 1.
0x2646:001
(P114.01)
DO actual frequency: Digital output 1
(DO actual freq.: Digital output 1)
•
Read only: x.x Hz
•
From version 05.00
Display of the current frequency of the pulse train signal at the digital
output 1.
I/O extensions and control connecons
Congure digital outputs
Digital output 1
271