Address Name / seng range / [default seng] Info
0x23A1:007
(P510.07)
EtherNet/IP sengs: Mulcast allocaon
(EtherN/IP se.: Mcast allocaon)
•
From version 02.00
Selecon for mulcast-IP addressing.
0 Default allocaon
1 Mulcast number/start address
0x23A1:008
(P510.08)
EtherNet/IP sengs: Mulcast IP address
(EtherN/IP se.: Mcast IP addr.)
0.0.0.0 ... [239.64.2.224] ... 255.255.255.255
•
From version 02.00
Set mulcast IP address.
The default seng 3221373167 corresponds to the Mulcast IP address
239.64.2.192.
•
3221373167 = 0xC00240EF à 0xEF.0x40.0x02.0xC0 = 239.64.2.192
0x23A1:009
(P510.09)
EtherNet/IP sengs: Mulcast number
(EtherN/IP se.: Mulcast number)
1 ... [1] ... 8
•
From version 02.00
Set mulcast number.
0x23A4:001
(P512.01)
Port sengs: Port 1
(Port sengs: Port 1)
•
From version 02.00
Set baud rate for Ethernet port 1.
0 Auto-Negoaon
1 10 Mbps
2 100 Mbps
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
0x23A4:002
(P512.02)
Port sengs: Port 2
(Port sengs: Port 2)
•
From version 02.00
Set baud rate for Ethernet port 2.
0 Auto-Negoaon
1 10 Mbps
2 100 Mbps
3 Reserved
4 Reserved
5 10 Mbps/Half Duplex
6 10 Mbps/Full Duplex
7 100 Mbps/Half Duplex
8 100 Mbps/Full Duplex
9 Reserved
10 Reserved
11 Reserved
12 Reserved
0x23A7
(P514.00)
Address conict detecon
(AddrConctDetec)
•
From version 02.00
Acvate address conict detecon (ACD) (enable).
•
If this value is changed, the device must be reset ("Power o/on" or
"Type 0 Reset").
0 Disabled
1 Enabled
0x400B:010 AC Drive mode Selecon of the AC drive mode.
0 Vendor specic
1 Speed control (open loop)
2 Speed control (closed loop)
3 Torque control (from version 03.00)
Conguring the network
EtherNet/IP
Basic seng and opons
399