Constant TRUE [1] Enable inverter
Digital input 2 [12]
Digital input 1 [11]
Local control active [104]
Remote control active [105]
Running [50]
Stop active [53]
Output signals
Status signals
Output frequency
Activate keypad control
Run
Input signals
Frequency setpoint selection
FunctionTrigger
The status signals can be assigned to digital outputs. 4Congure digital outputs ^ 263
①
When changing over to another control source, the motor is rst stopped with the stop method set in 0x2838:003 (P203.03).
②
The motor will also be stopped if the "Run" funcon is deacvated or the keypad key is pressed (irrespecve of the acve control
source).
③
Aer stopping with the keypad key and before a renewed start command from another control source, the key on the keypad must
be pressed to cancel the keypad stop again ("KSTOP").
Start, stop and rotang direcon commands
Changing the control source during operaon
Example: Change-over from terminal control to keypad control
80