1098
Program
Number
Program Name/Description
Input Data
Default
20-03-04
System Options for Single Line Telephones
Dial Sending Start Time for SLT or ARS
Set the time before the first digit is sent out.
When using a third-party external paging
device, set this option to 1. In addition, set
Program 20-03-03 to 1.
0 ~ 64800 seconds
3
20-03-05
System Options for Single Line Telephones
SLT Operation Mode
Define the Operation Mode for SLT terminals.
0 = Normal Mode
1 = Extended Mode1
2 = Extended Mode2
0
20-03-06
System Options for Single Line Telephones
Headset Ringing Start Time (for SLT)
Define the headset ringing start time. After this
time expires from the time when a single line
telephone is off-hook, the system sets the
single line telephone to headset ringing mode.
0 ~ 64800 seconds
5
20-03-07
System Options for Single Line Telephones
Trunk Call Dial Forced Sending Start Time
(Forced Dial)
Define the Trunk Call Dial Forced Sending Start
Time.
0 ~ 64800 seconds
0
20-06-01
Class of Service for Extensions
Assign a unique Class of Service for Dual OPX
telephones only when using Continued Dialing.
Day Night/Mode: 1 ~ 8
Class of Service of Extensions
(1 ~ 15)
Extension port
101 = Class 15
All other
extension port =
Class 1
20-13-13
Class of Service Options (Supplementary
Service) Continued Dialing (DTMF) Signal
on ICM Call
Turn Off or On an extension user ability to use
Continued Dialing, which allows DTMF signal
sending while talking on extension.
0 = Off
1 = On
COS 1 ~ 15 = 1
20-15-01
Ring Cycle Setup Normal Incoming Call on
Trunk
Define the ringing cycle (1 ~ 13) for normal
incoming trunk calls (DIL, ring group, etc.).
Ringing Cycle = 1 ~ 13
2
20-15-03
Ring Cycle Setup Incoming Internal Call
Define the ringing cycle (1 ~ 13) for ICM calls.
Ringing Cycle = 1 ~ 13
12
20-15-05
Ring Cycle Setup DID/DDI
Define the ringing cycle (1 ~ 13) for DID calls.
Ringing Cycle = 1 ~ 13
8
80-03-01
DTMF Tone Receiver Setup Detect Level
Use Items 11 ~ 32 to set the criteria for dial tone
detection for outgoing ARS calls.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
Type 1 ~ 5 = 0