Program
Number
Program Name/Description
Input Data
Default
84-06-04
PVA Data Setting Fract Lost Threshold
Define the fractional lost threshold. This data is
sent to the GCD-CP10 if the value exceeds the
defined value.
0 ~ 100%
0
84-06-05
PVA Data Setting Packets Lost Threshold
Define the packets lost threshold. This data is
sent to the GCD-CP10 when the value exceeds
the defined value.
0 ~ 16777215
0
84-06-07
PVA Data Setting Jitter Threshold
Define the Jitter Threshold. This data is sent to
the GCD-CP10 when the value exceeds the
defined value.
0 ~ 4294967295 seconds
0
84-06-09
PVA Data Setting Delay LSR Threshold
Define the Delay LSR threshold. This data is
sent to the GCD-CP10 when the value exceeds
the defined value.
0 ~ 4294967295 seconds
0
VoIP ToS Setup:
The UNIVERGE SV9100 supports Quality of Service (QoS) Marking for the Session Initiation
Protocol
(SIP).
Program
Number
Program Name/Description
Input Data
Default
84-10-01
ToS Setup ToS Mode
When Input Data is set to 1, Item No. 07 is
invalid. When Data is set to 2, Items
No. 02 ~ 06 are invalid.
0 = Disable (Invalid)
1 = IP Precedence
2 = Diffserv
0
IP Extension Numbering:
Program
Number
Program Name/Description
Input Data
Default
11-02-01
Extension Numbering
Define the IP Phone extension number.
Dial (maximum of eight digits).
1
101
2
102
3
103
~
~
99 199
100 3101
~
~
960 3961