416
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
10-03-01
(1)
ETU Setup (DLCA PKG Setup) Terminal
Type (B1)
Set up and confirm the Basic Configuration
data for terminal type (B1).
0 = Not set
1 = Multiline Terminal
3 = Bluetooth Cordless Handset
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Doorbox)
9 = PGD (ACI)
10 = DSS Console
11 = -- Not Used --
0
10-03-06
ETU Setup (DLCA PKG Setup) Terminal
Type (B2)
Set up and confirm the Basic Configuration
data for terminal type.
For DLC package support, set the terminal type
to 8 [PGD (for Door Box)]. First set 10-03-01 to
0 with no device plugged into that port, then
plug the device in and the system should
recognize it as a door box and then set
Program 10-03-06.
0 = Not set
6 = PGD(2)-U10 ADP (Paging)
7 = PGD(2)-U10 ADP (Tone
Ringer)
8 = PGD(2)-U10 ADP (Door
Box)
9 = PGD(2)-U10 ADP (ACI)
12 = APR (B2 Mode)
0
11-12-36
Service Code Access (for Service Access)
Door Box Access
If the service code for Doorphone Access is not
acceptable, change it here.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
802
15-07-01
Programmable Function Keys
Assign a function key for External Call Forward
by Doorphone (Code 54).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
32-01-01
Door Box Timers Door Box Answer Time
Set the time a user has to answer the Door Box
chimes.
0 ~ 64800 seconds
30